#!/bin/sh
#
# This will bring the network interface up.
#

# Splash.
#
echo "Executing /scripts/network_up..."

# Source Router type
#
. /app/scripts/eipr_type

if [ "$EIPR_TYPE" = "REALTEK" ]; then
	WANIF=eth0.2
	LANIF=eth0.1
else
	WANIF=eth1
	LANIF=eth0
fi

# Hostname
if [ -e /app/config/hn ]; then
	. /app/config/hn
	echo $EIPR_HN > /proc/sys/kernel/hostname
fi

# Domainname
if [ -e /app/config/dn ]; then
	. /app/config/dn
	echo $EIPR_DN > /proc/sys/kernel/domainname
fi


# Source the network definitions.
#
. /app/config/network_lan.ini
. /app/config/network_wan.ini

# Bring up the local interface.
#
/sbin/ifconfig lo 127.0.0.1 up
/sbin/route add -net 127.0.0.0 netmask 255.0.0.0 lo

if [ "$EIPR_VPN" = "YES" ] && [ "$VPN_MODE" = "SERVER" ]; then
	#set bridge with LAN interface
	/etc/openvpn/server/set_bridge.sh

	# set LAN interface to be bridge
	LANIF=br0
fi


#
# Setup eth0.1 (LAN) port. It will be fixed ip
#
echo "Manually initializing LANIF to $IPADDR_LAN..."
/sbin/ifconfig $LANIF $IPADDR_LAN netmask $NETMASK_LAN up


#initial iptables rule that flush and set chain rules
/scripts/iptables_Init1

#
# If LAN CLients need DHCP server, start it
#
if [ "$BOOTPROTO_LAN_CLIENT" = "dhcp" ]
then
	#copy the old leases file that was present before reboot
	if [ -e /app/config/udhcpd.leases ]; then
		mv /app/config/udhcpd.leases /tmp/udhcpd.leases
	else
		touch /tmp/udhcpd.leases
	fi

	echo "Starting DHCP Server on LAN Port..."
        udhcpd >/dev/null 2>&1	
fi

#
# Delete resolv.conf files (both original and ppp)
#
rm /etc/ppp/resolv.conf
rm /etc/resolv.conf
#
# Setup eth0.2 (WAN) port. It will be either dhcp, fixed ip or ppp
#
if [ "$BOOTPROTO_WAN" = "ppp" ]
then
	# Bring up the eth0.2/WAN interface for ppp
	/sbin/ifconfig $WANIF up
	/usr/bin/pon &
elif [ "$BOOTPROTO_WAN" = "pptp" ]
then
	# Bring up the eth0.2/WAN interface for pptp
	/sbin/ifconfig $WANIF $IPADDR_WAN netmask $NETMASK_WAN up
	# Add a route for it.
	/sbin/route add default gw $GATEWAY_WAN $WANIF
	# Start PPTP
	/usr/bin/pon &
elif [ "$BOOTPROTO_WAN" = "dhcp" ]
then
	# Start the dhcp daemon daemon.
	# This should try forever to start DHCP.
	# It will also create /etc/resolv.conf and add routes
	echo "Starting DHCP Client on WAN Port..."
	/sbin/ifconfig $WANIF mtu $MTU_WAN
	if [ -e /app/config/hn ]; then
		udhcpc -i $WANIF -b -R -h $EIPR_HN -p /var/run/udhcpc.$WANIF -s /usr/share/udhcpc/modified.script >/dev/null 2>&1
	else
		udhcpc -i $WANIF -b -R -p /var/run/udhcpc.$WANIF -s /usr/share/udhcpc/modified.script >/dev/null 2>&1
	fi
elif [ "$BOOTPROTO_WAN" = "cellular" ]
then
	# enable cellular power
	echo 0 > /sys/class/gpio/gpio13/value
	/app/config/cell/startCell.sh &
else
	# Bring up the interface manually.
	echo "Manually initializing eth0.2/WAN to $IPADDR_WAN..."
	/sbin/ifconfig $WANIF $IPADDR_WAN netmask $NETMASK_WAN mtu $MTU_WAN up
	# Create resolv.conf
	echo "nameserver $DNS_SERVER1_WAN"  > /etc/resolv.conf
	echo "nameserver $DNS_SERVER2_WAN" >> /etc/resolv.conf
	# Add a route for it.
	/sbin/route add default gw $GATEWAY_WAN $WANIF

	if [ "$EIPR_VPN" = "YES" ]
        then
                /app/scripts/startopenvpn.sh & # startopenvpn
        fi
fi

# if WAN port (eth0.2) is set for DHCP, then dhcp script starts DNS
# if WAN port (eth0.2) is set for PPPoE/PPTP, then PPPoE/PPTP starts DNS. 
# else we start it here for fixed ip.
if [ "$BOOTPROTO_WAN" = "none" ];then
	/app/scripts/startdns &
fi

# And exit.
#
exit 0
