#!/bin/sh
#***********************************************************************
#
# pppoe-setup
#
# All-purpose slicing/dicing shell script to configure rp-pppoe.
#
# LIC: GPL
#
# Copyright (C) 2000 Roaring Penguin Software Inc.
#
# $Id: pppoe-setup.in,v 1.2 2005/08/10 00:25:18 dfs Exp $
#***********************************************************************

# From AUTOCONF
prefix=/usr
exec_prefix=${prefix}

# Paths to programs
IFCONFIG=/sbin/ifconfig
PPPD=/usr/sbin/pppd
PPPOE=${exec_prefix}/sbin/pppoe
ECHO=/bin/echo
LOGGER="/usr/bin/logger -t `basename $0`"

# Set to "C" locale so we can parse messages from commands
LANG=C
export LANG

CONFIG=/etc/ppp/pppoe.conf

# Protect created files
umask 077

copy() {
    cp $1 $2
    if [ "$?" != 0 ] ; then
	$ECHO "*** Error copying $1 to $2"
	$ECHO "*** Quitting."
	exit 1
    fi
}

$ECHO "Welcome to the Roaring Penguin PPPoE client setup.  First, I will run"
$ECHO "some checks on your system to make sure the PPPoE client is installed"
$ECHO "properly..."
$ECHO ""

# Must be root
if [ "`/usr/bin/id -u`" != 0 ] ; then
    $ECHO "$0: Sorry, you must be root to run this script"
    exit 1
fi

# Prototype config file must exist
if [ ! -r "$CONFIG" ] ; then
    $ECHO "Oh, dear, I don't see the file '$CONFIG' anywhere.  Please"
    $ECHO "re-install the PPPoE client."
    exit 1
fi

# Must have pppd
if [ ! -x $PPPD ] ; then
    $ECHO "Oops, I can't execute the program '$PPPD'.  You"
    $ECHO "must install the PPP software suite, version 2.3.10 or later."
    exit 1
fi
export CONFIG
. $CONFIG

if [ "$DEMAND" = "" ] ; then
    DEMAND=no
fi

# pppoe must exist
if [ ! -x "$PPPOE" ] ; then
    $ECHO "Oh, dear, I can't execute the program '$PPPOE'.  Please"
    $ECHO "re-install the rp-pppoe client."
    exit 1
fi

$ECHO "Looks good!  Now, please enter some information:"

while [ true ] ; do
    $ECHO ""
    $ECHO "USER NAME"
    $ECHO ""
    printf "%s" ">>> Enter your PPPoE user name (default $USER): "
    read U

    if [ "$U" = "" ] ; then
	U="$USER"
    fi

    # Under Linux, "fix" the default interface if eth1 is not available
    if test `uname -s` = "Linux" ; then
	$IFCONFIG $ETH > /dev/null 2>&1 || ETH=eth0
    fi
    $ECHO ""
    $ECHO "INTERFACE"
    $ECHO ""
    $ECHO ">>> Enter the Ethernet interface connected to the DSL modem"
    $ECHO "For Solaris, this is likely to be something like /dev/hme0."
    $ECHO "For Linux, it will be ethn, where 'n' is a number."
    printf "%s" "(default $ETH): "
    read E

    if [ "$E" = "" ] ; then
	E="$ETH"
    fi

    $ECHO ""
    $ECHO "Do you want the link to come up on demand, or stay up continuously?"
    $ECHO "If you want it to come up on demand, enter the idle time in seconds"
    $ECHO "after which the link should be dropped.  If you want the link to"
    $ECHO "stay up permanently, enter 'no' (two letters, lower-case.)"
    $ECHO "NOTE: Demand-activated links do not interact well with dynamic IP"
    $ECHO "addresses.  You may have some problems with demand-activated links."
    printf "%s" ">>> Enter the demand value (default $DEMAND): "
    read D
    if [ "$D" = "" ] ; then
	D=$DEMAND
    fi

    $ECHO ""
    $ECHO "DNS"
    $ECHO ""
    $ECHO "Please enter the IP address of your ISP's primary DNS server."
    $ECHO "If your ISP claims that 'the server will provide DNS addresses',"
    $ECHO "enter 'server' (all lower-case) here."
    $ECHO "If you just press enter, I will assume you know what you are"
    $ECHO "doing and not modify your DNS setup."
    printf "%s" ">>> Enter the DNS information here: "

    read DNS1


    if [ "$DNS1" != "" ] ; then
        if [ "$DNS1" != "server" ] ; then
	    $ECHO "Please enter the IP address of your ISP's secondary DNS server."
	    $ECHO "If you just press enter, I will assume there is only one DNS server."
	    printf "%s" ">>> Enter the secondary DNS server address here: "
	    read DNS2
	fi
    fi

    while [ true ] ; do
	$ECHO ""
	$ECHO "PASSWORD"
	$ECHO ""
	stty -echo
	printf "%s" ">>> Please enter your PPPoE password:    "
	read PWD1
	$ECHO ""
	printf "%s" ">>> Please re-enter your PPPoE password: "
	read PWD2
	$ECHO ""
	stty echo
	if [ "$PWD1" = "$PWD2" ] ; then
	    break
	fi

	printf "%s" ">>> Sorry, the passwords do not match.  Try again? (y/n)"
	read ANS
	case "$ANS" in
	    N|No|NO|Non|n|no|non)
		$ECHO "OK, quitting.  Bye."
		exit 1
	esac
    done

    # Firewalling
    $ECHO ""
    $ECHO "FIREWALLING"
    $ECHO ""
    if test `uname -s` != "Linux" ; then
	$ECHO "Sorry, firewalling is only supported under Linux.  Consult"
	$ECHO "your operating system manuals for details on setting up"
	$ECHO "packet filters for your system."
	FIREWALL=NONE
    else
	$ECHO "Please choose the firewall rules to use.  Note that these rules are"
	$ECHO "very basic.  You are strongly encouraged to use a more sophisticated"
	$ECHO "firewall setup; however, these will provide basic security.  If you"
	$ECHO "are running any servers on your machine, you must choose 'NONE' and"
	$ECHO "set up firewalling yourself.  Otherwise, the firewall rules will deny"
	$ECHO "access to all standard servers like Web, e-mail, ftp, etc.  If you"
	$ECHO "are using SSH, the rules will block outgoing SSH connections which"
	$ECHO "allocate a privileged source port."
	$ECHO ""
	while [ true ] ; do
	    $ECHO "The firewall choices are:"
	    $ECHO "0 - NONE: This script will not set any firewall rules.  You are responsible"
	    $ECHO "          for ensuring the security of your machine.  You are STRONGLY"
	    $ECHO "          recommended to use some kind of firewall rules."
	    $ECHO "1 - STANDALONE: Appropriate for a basic stand-alone web-surfing workstation"
	    $ECHO "2 - MASQUERADE: Appropriate for a machine acting as an Internet gateway"
	    $ECHO "                for a LAN"
	    printf "%s" ">>> Choose a type of firewall (0-2): "
	    read a
	    if [ "$a" = 0 -o "$a" = 1 -o "$a" = 2 ] ; then
		break
	    fi
	    $ECHO "Please enter a number from 0 to 2"
	done

	case "$a" in
	    0)
		FIREWALL=NONE
		;;
	    1)
		FIREWALL=STANDALONE
		;;
	    2)
		FIREWALL=MASQUERADE
		;;
	esac
    fi

    $ECHO ""
    $ECHO "** Summary of what you entered **"
    $ECHO ""
    $ECHO "Ethernet Interface: $E"
    $ECHO "User name:          $U"
    if [ "$D" = "no" ] ; then
	$ECHO "Activate-on-demand: No"
    else
	$ECHO "Activate-on-demand: Yes; idle timeout = $D seconds"
    fi

    if [ "$DNS1" != "" ] ; then
        if [ "$DNS1" = "server" ] ; then
	    $ECHO "DNS addresses:      Supplied by ISP's server"
        else
	    $ECHO "Primary DNS:        $DNS1"
	    if [ "$DNS2" != "" ] ; then
		$ECHO "Secondary DNS:      $DNS2"
	    fi
        fi
    else
	$ECHO "DNS:                Do not adjust"
    fi
    $ECHO "Firewalling:        $FIREWALL"
    $ECHO ""
    while [ true ] ; do
        printf "%s" '>>> Accept these settings and adjust configuration files (y/n)? '
        read ANS
	case "ANS" in
	    Y|y|yes|Yes|oui|Oui)
		ANS=y
		;;
            N|n|no|No|non|Non)
		ANS=n
		;;
	esac
	if [ "$ANS" = "y" -o "$ANS" = "n" ] ; then
	    break
        fi
    done
    if [ "$ANS" = "y" ] ; then
	break
    fi
done

# Adjust configuration files.  First to $CONFIG

$ECHO "Adjusting $CONFIG"

copy $CONFIG $CONFIG-bak
if [ "$DNS1" = "server" ] ; then
    DNSTYPE=SERVER
    DNS1=""
    PEERDNS=yes
else
    PEERDNS=no
    if [ "$DNS1" = "" ] ; then
	DNSTYPE=NOCHANGE
    else
	DNSTYPE=SPECIFY
    fi
fi

# Where is pppd likely to put its pid?
if [ -d /var/run ] ; then
    VARRUN=/var/run
else
    VARRUN=/etc/ppp
fi

# Some #$(*& ISP's use a slash in the user name...
sed -e "s&^USER=.*&USER='$U'&" \
    -e "s&^ETH=.*&ETH='$E'&" \
    -e "s&^PIDFILE=.*&PIDFILE=\"$VARRUN/\$CF_BASE-pppoe.pid\"&" \
    -e "s/^FIREWALL=.*/FIREWALL=$FIREWALL/" \
    -e "s/^DEMAND=.*/DEMAND=$D/" \
    -e "s/^DNSTYPE=.*/DNSTYPE=$DNSTYPE/" \
    -e "s/^DNS1=.*/DNS1=$DNS1/" \
    -e "s/^DNS2=.*/DNS2=$DNS2/" \
    -e "s/^PEERDNS=.*/PEERDNS=$PEERDNS/" \
    < $CONFIG-bak > $CONFIG

if [ $? != 0 ] ; then
    $ECHO "** Error modifying $CONFIG"
    $ECHO "** Quitting"
    exit 1
fi

if [ "$DNS1" != "" ] ; then
    if [ "$DNS1" != "server" ] ; then
	$ECHO "Adjusting /etc/resolv.conf"
	if [ -r /etc/resolv.conf ] ; then
	    grep -s "MADE-BY-RP-PPPOE" /etc/resolv.conf > /dev/null 2>&1
	    if [ "$?" != 0 ] ; then
		$ECHO "  (But first backing it up to /etc/resolv.conf-bak)"
		copy /etc/resolv.conf /etc/resolv.conf-bak
	    fi
	fi
	$ECHO "# MADE-BY-RP-PPPOE" > /etc/resolv.conf
	$ECHO "nameserver $DNS1" >> /etc/resolv.conf
	if [ "$DNS2" != "" ] ; then
	    $ECHO "nameserver $DNS2" >> /etc/resolv.conf
	fi
    fi
fi

$ECHO "Adjusting /etc/ppp/pap-secrets and /etc/ppp/chap-secrets"
if [ -r /etc/ppp/pap-secrets ] ; then
    $ECHO "  (But first backing it up to /etc/ppp/pap-secrets-bak)"
    copy /etc/ppp/pap-secrets /etc/ppp/pap-secrets-bak
else
    cp /dev/null /etc/ppp/pap-secrets-bak
fi
if [ -r /etc/ppp/chap-secrets ] ; then
    $ECHO "  (But first backing it up to /etc/ppp/chap-secrets-bak)"
    copy /etc/ppp/chap-secrets /etc/ppp/chap-secrets-bak
else
    cp /dev/null /etc/ppp/chap-secrets-bak
fi

egrep -v "^$U|^\"$U\"" /etc/ppp/pap-secrets-bak > /etc/ppp/pap-secrets
$ECHO "\"$U\"	*	\"$PWD1\"" >> /etc/ppp/pap-secrets
egrep -v "^$U|^\"$U\"" /etc/ppp/chap-secrets-bak > /etc/ppp/chap-secrets
$ECHO "\"$U\"	*	\"$PWD1\"" >> /etc/ppp/chap-secrets

$ECHO ""
$ECHO ""
$ECHO ""
$ECHO "Congratulations, it should be all set up!"
$ECHO ""
$ECHO "Type 'pppoe-start' to bring up your PPPoE link and 'pppoe-stop' to bring"
$ECHO "it down.  Type 'pppoe-status' to see the link status."
exit 0
